Eaton 9PX 1000i RT2U
Technology : On-line double conversion with Power Factor Correction (PFC) system
Format : RT2U (tower/rack 2U)
Rating (VA/Watts) : 1000VA/1000W
Connection :
- Output Connections : 8 IEC C13 (10A) sockets
- Switched outlet group : 2 outlet groups
Input voltage : 200/208/220/230/240V
Input Voltage Range : 176-276V without derating (up to 100-276V with derating)
Input frequency range : 40-70Hz, 50/60Hz autoselection, frequency converter mode
Communication Ports :
- 1 USB port + 1 serial RS232 port + 1 mini-terminal block for remote ON/OFF
- 1 mini-terminal block for remote power off + 1 mini-terminal block for output relay
Communication slot : 1 slot for Network-MS card (included in netpack versions), ModBus-MS or Relay-MS cards
Dimensions H x W x D : 86.5x440x450 (mm)
Weight : 17.4 (kg)
Warranty : 3Yrs On-Site
Technology : On-line double conversion with Power Factor Correction (PFC) system
Format : RT2U (tower/rack 2U)
Rating (VA/Watts) : 1000VA/1000W
Connection :
- Output Connections : 8 IEC C13 (10A) sockets
- Switched outlet group : 2 outlet groups
Input voltage : 200/208/220/230/240V
Input Voltage Range : 176-276V without derating (up to 100-276V with derating)
Input frequency range : 40-70Hz, 50/60Hz autoselection, frequency converter mode
Communication Ports :
- 1 USB port + 1 serial RS232 port + 1 mini-terminal block for remote ON/OFF
- 1 mini-terminal block for remote power off + 1 mini-terminal block for output relay
Communication slot : 1 slot for Network-MS card (included in netpack versions), ModBus-MS or Relay-MS cards
Dimensions H x W x D : 86.5x440x450 (mm)
Weight : 17.4 (kg)
Warranty : 3Yrs On-Site
Eaton 9PX 2200i RT2U
Technology : On-line double conversion with Power Factor Correction (PFC) system
Format : RT2U (tower/rack 2U) and RT3U (tower/rack 3U)
Rating (VA/Watts) : 2200VA/2200W
Connection :
- Output Connections : 8 IEC C13 (10A) sockets + 2 IEC C19 (16A) sockets
- Switched outlet group : 2 outlet groups
Input voltage : 200/208/220/230/240V
Input Voltage Range : 176-276V without derating (up to 100-276V with derating)
Input frequency range : 40-70Hz, 50/60Hz autoselection, frequency converter mode
Communication Ports :
- 1 USB port + 1 serial RS232 port + 1 mini-terminal block for remote ON/OFF
- 1 mini-terminal block for remote power off + 1 mini-terminal block for output relay
Communication slot : 1 slot for Network-MS card (included in netpack versions), ModBus-MS or Relay-MS cards
Dimensions H x W x D : 2U : 86.5x440x605 / 3U : 130x440x485
Weight : 25 kg / 24.5 kg
Warranty : 3Yrs On-Site
Technology : On-line double conversion with Power Factor Correction (PFC) system
Format : RT2U (tower/rack 2U) and RT3U (tower/rack 3U)
Rating (VA/Watts) : 2200VA/2200W
Connection :
- Output Connections : 8 IEC C13 (10A) sockets + 2 IEC C19 (16A) sockets
- Switched outlet group : 2 outlet groups
Input voltage : 200/208/220/230/240V
Input Voltage Range : 176-276V without derating (up to 100-276V with derating)
Input frequency range : 40-70Hz, 50/60Hz autoselection, frequency converter mode
Communication Ports :
- 1 USB port + 1 serial RS232 port + 1 mini-terminal block for remote ON/OFF
- 1 mini-terminal block for remote power off + 1 mini-terminal block for output relay
Communication slot : 1 slot for Network-MS card (included in netpack versions), ModBus-MS or Relay-MS cards
Dimensions H x W x D : 2U : 86.5x440x605 / 3U : 130x440x485
Weight : 25 kg / 24.5 kg
Warranty : 3Yrs On-Site
Eaton 9PX Lithium 1000i RT2U
Technology : On-line double conversion with Power Factor Correction (PFC) system
Format : RT2U (tower/rack 2U)
Rating (VA/Watts) : 1000VA/1000W
Connection :
- Input Connections : 1 IEC C14 (10A)
- Output Connections : 8 IEC C13 (10A) sockets
- Switched outlet group : 2 outlet groups
Input voltage : 200/208/220/230/240V
Input Voltage Range : 176-276V without derating (up to 100-276V with derating)
Input frequency range : 40-70Hz, 50/60Hz autoselection, frequency converter mode
Communication Ports :
- 1 USB port + 1 serial RS232 port + 1 mini-terminal block for remote ON/OFF
- 1 mini-terminal block for remote power off + 1 mini-terminal block for output relay
Communication slot : 1 slot for Gigabit Network management card (included in netpack versions), Industrial Gateway Card (Modbus TCP/RTU) or Relay card.
Dimensions H x W x D : 86.5x440x450 (mm)
Weight : 15.6Kg
Warranty : 5Yrs On-Site
Technology : On-line double conversion with Power Factor Correction (PFC) system
Format : RT2U (tower/rack 2U)
Rating (VA/Watts) : 1000VA/1000W
Connection :
- Input Connections : 1 IEC C14 (10A)
- Output Connections : 8 IEC C13 (10A) sockets
- Switched outlet group : 2 outlet groups
Input voltage : 200/208/220/230/240V
Input Voltage Range : 176-276V without derating (up to 100-276V with derating)
Input frequency range : 40-70Hz, 50/60Hz autoselection, frequency converter mode
Communication Ports :
- 1 USB port + 1 serial RS232 port + 1 mini-terminal block for remote ON/OFF
- 1 mini-terminal block for remote power off + 1 mini-terminal block for output relay
Communication slot : 1 slot for Gigabit Network management card (included in netpack versions), Industrial Gateway Card (Modbus TCP/RTU) or Relay card.
Dimensions H x W x D : 86.5x440x450 (mm)
Weight : 15.6Kg
Warranty : 5Yrs On-Site
Eaton 9PX 3000i RT2U
Technology : On-line double conversion with Power Factor Correction (PFC) system
Format : RT2U (tower/rack 2U) and RT3U (tower/rack 3U)
Rating (VA/Watts) : 3000VA/3000W
Connection :
- Output Connections : 8 IEC C13 (10A) sockets + 2 IEC C19 (16A) sockets
- Switched outlet group : 2 outlet groups
Input voltage : 200/208/220/230/240V
Input Voltage Range : 176-276V without derating (up to 100-276V with derating)
Input frequency range : 40-70Hz, 50/60Hz autoselection, frequency converter mode
Communication Ports :
- 1 USB port + 1 serial RS232 port + 1 mini-terminal block for remote ON/OFF
- 1 mini-terminal block for remote power off + 1 mini-terminal block for output relay
Communication slot : 1 slot for Network-MS card (included in netpack versions), ModBus-MS or Relay-MS cards
Dimensions H x W x D : 2U : 86.5x440x605 / 3U : 130x440x485
Weight : 27.6 kg / 27.4 kg
Warranty : 3Yrs On-Site
Technology : On-line double conversion with Power Factor Correction (PFC) system
Format : RT2U (tower/rack 2U) and RT3U (tower/rack 3U)
Rating (VA/Watts) : 3000VA/3000W
Connection :
- Output Connections : 8 IEC C13 (10A) sockets + 2 IEC C19 (16A) sockets
- Switched outlet group : 2 outlet groups
Input voltage : 200/208/220/230/240V
Input Voltage Range : 176-276V without derating (up to 100-276V with derating)
Input frequency range : 40-70Hz, 50/60Hz autoselection, frequency converter mode
Communication Ports :
- 1 USB port + 1 serial RS232 port + 1 mini-terminal block for remote ON/OFF
- 1 mini-terminal block for remote power off + 1 mini-terminal block for output relay
Communication slot : 1 slot for Network-MS card (included in netpack versions), ModBus-MS or Relay-MS cards
Dimensions H x W x D : 2U : 86.5x440x605 / 3U : 130x440x485
Weight : 27.6 kg / 27.4 kg
Warranty : 3Yrs On-Site
Eaton 9PX Lithium 2200i RT2U
Technology : On-line double conversion with Power Factor Correction (PFC) system
Format : RT2U (tower/rack 2U)
Rating (VA/Watts) : 2200VA/2200W
Connection :
- Input Connections : 1 IEC C20 (16A)
- Output Connections : 8 IEC C13 (10A) sockets + 2 IEC C19 (16A) sockets
- Switched outlet group : 2 outlet groups
Input voltage : 200/208/220/230/240V
Input Voltage Range : 176-276V without derating (up to 100-276V with derating)
Input frequency range : 40-70Hz, 50/60Hz autoselection, frequency converter mode
Communication Ports :
- 1 USB port + 1 serial RS232 port + 1 mini-terminal block for remote ON/OFF
- 1 mini-terminal block for remote power off + 1 mini-terminal block for output relay
Communication slot : 1 slot for Gigabit Network management card (included in netpack versions), Industrial Gateway Card (Modbus TCP/RTU) or Relay card.
Dimensions H x W x D : 86.5x440x605 (mm)
Weight : 22.1Kg
Warranty : 5Yrs On-Site
Technology : On-line double conversion with Power Factor Correction (PFC) system
Format : RT2U (tower/rack 2U)
Rating (VA/Watts) : 2200VA/2200W
Connection :
- Input Connections : 1 IEC C20 (16A)
- Output Connections : 8 IEC C13 (10A) sockets + 2 IEC C19 (16A) sockets
- Switched outlet group : 2 outlet groups
Input voltage : 200/208/220/230/240V
Input Voltage Range : 176-276V without derating (up to 100-276V with derating)
Input frequency range : 40-70Hz, 50/60Hz autoselection, frequency converter mode
Communication Ports :
- 1 USB port + 1 serial RS232 port + 1 mini-terminal block for remote ON/OFF
- 1 mini-terminal block for remote power off + 1 mini-terminal block for output relay
Communication slot : 1 slot for Gigabit Network management card (included in netpack versions), Industrial Gateway Card (Modbus TCP/RTU) or Relay card.
Dimensions H x W x D : 86.5x440x605 (mm)
Weight : 22.1Kg
Warranty : 5Yrs On-Site
Eaton 9PX Lithium 3000i RT2U
Technology : On-line double conversion with Power Factor Correction (PFC) system
Format : RT2U (tower/rack 2U)
Rating (VA/Watts) : 3000VA/3000W
Connection :
- Input Connections : 1 IEC C20 (16A)
- Output Connections : 8 IEC C13 (10A) sockets + 2 IEC C19 (16A) sockets
- Switched outlet group : 2 outlet groups
Input voltage : 200/208/220/230/240V
Input Voltage Range : 176-276V without derating (up to 100-276V with derating)
Input frequency range : 40-70Hz, 50/60Hz autoselection, frequency converter mode
Communication Ports :
- 1 USB port + 1 serial RS232 port + 1 mini-terminal block for remote ON/OFF
- 1 mini-terminal block for remote power off + 1 mini-terminal block for output relay
Communication slot : 1 slot for Gigabit Network management card (included in netpack versions), Industrial Gateway Card (Modbus TCP/RTU) or Relay card.
Dimensions H x W x D : 86.5x440x605 (mm)
Weight : 22.8 Kg
Warranty : 5Yrs On-Site
Technology : On-line double conversion with Power Factor Correction (PFC) system
Format : RT2U (tower/rack 2U)
Rating (VA/Watts) : 3000VA/3000W
Connection :
- Input Connections : 1 IEC C20 (16A)
- Output Connections : 8 IEC C13 (10A) sockets + 2 IEC C19 (16A) sockets
- Switched outlet group : 2 outlet groups
Input voltage : 200/208/220/230/240V
Input Voltage Range : 176-276V without derating (up to 100-276V with derating)
Input frequency range : 40-70Hz, 50/60Hz autoselection, frequency converter mode
Communication Ports :
- 1 USB port + 1 serial RS232 port + 1 mini-terminal block for remote ON/OFF
- 1 mini-terminal block for remote power off + 1 mini-terminal block for output relay
Communication slot : 1 slot for Gigabit Network management card (included in netpack versions), Industrial Gateway Card (Modbus TCP/RTU) or Relay card.
Dimensions H x W x D : 86.5x440x605 (mm)
Weight : 22.8 Kg
Warranty : 5Yrs On-Site
Eaton 9PX 6000i RT6U 3:1 withRack kit and Network card
Technical specifications
Rating (VA/W) : 6000VA/5400W
Electrical characteristics
Technology : On-line double-conversion with Power Factor Correction (PFC) system
Nominal voltage : 380/400/415 3:1
Input Voltage Range : 305V-480V without derating (up to 175V-480V with derating) 3:1
Output voltage/THDU : 200/208/220/230/240V +/– 1%; THDU <2%
Input frequency range/THDI : 40-70Hz, 50/60Hz autoselection, frequency converter as standard, THDI < 5%
Efficiency : Up to 94% in Online mode, 98% in Hi-Efficiency mode
Connections
Input : Terminal block (up to 16mm)
Outputs : Terminal block
Outputs with HotSwap Maintenance Bypass : Terminal block + 4 IEC C19 (16A)
Communication
Communication ports : 1 USB port, 1 RS232 serial port (USB and RS232 ports cannot be used simultaneously)
4 dry contacts (DB9), 1 mini terminal block for remote On/ Off and 1 for remote power Off
1 DB15 for parallel operation
Communication slot : 1 slot for Network-MS card, ModBus-MS or Relay-MS cards
Dimensions (H x W x D, mm) : 440 x 260 x 700
Weight (kg) : 88
Warranty : 3 Yrs On-Site Service by Eaton (Thailand)
Technical specifications
Rating (VA/W) : 6000VA/5400W
Electrical characteristics
Technology : On-line double-conversion with Power Factor Correction (PFC) system
Nominal voltage : 380/400/415 3:1
Input Voltage Range : 305V-480V without derating (up to 175V-480V with derating) 3:1
Output voltage/THDU : 200/208/220/230/240V +/– 1%; THDU <2%
Input frequency range/THDI : 40-70Hz, 50/60Hz autoselection, frequency converter as standard, THDI < 5%
Efficiency : Up to 94% in Online mode, 98% in Hi-Efficiency mode
Connections
Input : Terminal block (up to 16mm)
Outputs : Terminal block
Outputs with HotSwap Maintenance Bypass : Terminal block + 4 IEC C19 (16A)
Communication
Communication ports : 1 USB port, 1 RS232 serial port (USB and RS232 ports cannot be used simultaneously)
4 dry contacts (DB9), 1 mini terminal block for remote On/ Off and 1 for remote power Off
1 DB15 for parallel operation
Communication slot : 1 slot for Network-MS card, ModBus-MS or Relay-MS cards
Dimensions (H x W x D, mm) : 440 x 260 x 700
Weight (kg) : 88
Warranty : 3 Yrs On-Site Service by Eaton (Thailand)
Eaton 9PX 8000i RT6U 3:1 with Rack kit and Network card
Technical specifications
Rating (VA/W) : 8000VA/7200W
Electrical characteristics
Technology : On-line double-conversion with Power Factor Correction (PFC) system
Nominal voltage : 380/400/415 3:1
Input Voltage Range : 305V-480V without derating (up to 175V-480V with derating) 3:1
Output voltage/THDU : 200/208/220/230/240V +/– 1%; THDU <2%
Input frequency range/THDI : 40-70Hz, 50/60Hz autoselection, frequency converter as standard, THDI < 5%
Efficiency : Up to 95% in Online mode, 98% in Hi-Efficiency mode
Connections
Input : Terminal block (up to 16mm)
Outputs : Terminal block
Outputs with HotSwap Maintenance Bypass : Terminal block + 4 IEC C19 (16A)
Communication
Communication ports : 1 USB port, 1 RS232 serial port (USB and RS232 ports cannot be used simultaneously)
4 dry contacts (DB9), 1 mini terminal block for remote On/ Off and 1 for remote power Off
1 DB15 for parallel operation
Communication slot : 1 slot for Network-MS card, ModBus-MS or Relay-MS cards
Dimensions (H x W x D, mm) : 440 x 260 x 700
Weight (kg) : 88
Warranty : 2 Yrs On-Site Service by Eaton (Thailand)
Technical specifications
Rating (VA/W) : 8000VA/7200W
Electrical characteristics
Technology : On-line double-conversion with Power Factor Correction (PFC) system
Nominal voltage : 380/400/415 3:1
Input Voltage Range : 305V-480V without derating (up to 175V-480V with derating) 3:1
Output voltage/THDU : 200/208/220/230/240V +/– 1%; THDU <2%
Input frequency range/THDI : 40-70Hz, 50/60Hz autoselection, frequency converter as standard, THDI < 5%
Efficiency : Up to 95% in Online mode, 98% in Hi-Efficiency mode
Connections
Input : Terminal block (up to 16mm)
Outputs : Terminal block
Outputs with HotSwap Maintenance Bypass : Terminal block + 4 IEC C19 (16A)
Communication
Communication ports : 1 USB port, 1 RS232 serial port (USB and RS232 ports cannot be used simultaneously)
4 dry contacts (DB9), 1 mini terminal block for remote On/ Off and 1 for remote power Off
1 DB15 for parallel operation
Communication slot : 1 slot for Network-MS card, ModBus-MS or Relay-MS cards
Dimensions (H x W x D, mm) : 440 x 260 x 700
Weight (kg) : 88
Warranty : 2 Yrs On-Site Service by Eaton (Thailand)
Eaton 9PX 11000i RT6U 3:1 with Rack kit and Network card
Technical specifications
Rating (VA/W) : 11000VA/10000W
Electrical characteristics
Technology : On-line double-conversion with Power Factor Correction (PFC) system
Nominal voltage : 380/400/415 3:1
Input Voltage Range : 305V-480V without derating (up to 175V-480V with derating) 3:1
Output voltage/THDU : 200/208/220/230/240V +/– 1%; THDU <2%
Input frequency range/THDI : 40-70Hz, 50/60Hz autoselection, frequency converter as standard, THDI < 5%
Efficiency : Up to 95% in Online mode, 98% in Hi-Efficiency mode
Connections
Input : Terminal block (up to 16mm)
Outputs : Terminal block
Outputs with HotSwap Maintenance Bypass : Terminal block + 4 IEC C19 (16A)
Communication
Communication ports : 1 USB port, 1 RS232 serial port (USB and RS232 ports cannot be used simultaneously)
4 dry contacts (DB9), 1 mini terminal block for remote On/ Off and 1 for remote power Off
1 DB15 for parallel operation
Communication slot : 1 slot for Network-MS card, ModBus-MS or Relay-MS cards
Dimensions (H x W x D, mm) : 440 x 260 x 700
Weight (kg) : 88
Warranty : 2 Yrs On-Site Service by Eaton (Thailand)
Technical specifications
Rating (VA/W) : 11000VA/10000W
Electrical characteristics
Technology : On-line double-conversion with Power Factor Correction (PFC) system
Nominal voltage : 380/400/415 3:1
Input Voltage Range : 305V-480V without derating (up to 175V-480V with derating) 3:1
Output voltage/THDU : 200/208/220/230/240V +/– 1%; THDU <2%
Input frequency range/THDI : 40-70Hz, 50/60Hz autoselection, frequency converter as standard, THDI < 5%
Efficiency : Up to 95% in Online mode, 98% in Hi-Efficiency mode
Connections
Input : Terminal block (up to 16mm)
Outputs : Terminal block
Outputs with HotSwap Maintenance Bypass : Terminal block + 4 IEC C19 (16A)
Communication
Communication ports : 1 USB port, 1 RS232 serial port (USB and RS232 ports cannot be used simultaneously)
4 dry contacts (DB9), 1 mini terminal block for remote On/ Off and 1 for remote power Off
1 DB15 for parallel operation
Communication slot : 1 slot for Network-MS card, ModBus-MS or Relay-MS cards
Dimensions (H x W x D, mm) : 440 x 260 x 700
Weight (kg) : 88
Warranty : 2 Yrs On-Site Service by Eaton (Thailand)
Eaton 9PX 11000i RT6U with Rack kit
Technical specifications
Rating (VA/W) : 11000VA/10000W
Electrical characteristics
Technology : On-line double-conversion with Power Factor Correction (PFC) system
Input Voltage Range : 176-276V without derating (up to 100–276V with derating)
Input frequency range/THDI : 40-70Hz, 50/60Hz autoselection, frequency converter as standard, THDI < 5%
Efficiency : Up to 95% in Online mode, 98% in Hi-Efficiency mode
Connections
Input : Terminal block (up to 16mm)
Outputs : Terminal block
Outputs with HotSwap Maintenance Bypass : Terminal block + 4 IEC C19 (16A)
Communication
Communication ports : 1 USB port, 1 RS232 serial port (USB and RS232 ports cannot be used simultaneously)
4 dry contacts (DB9), 1 mini terminal block for remote On/ Off and 1 for remote power Off
1 DB15 for parallel operation
Communication slot : 1 slot for Network-MS card, ModBus-MS or Relay-MS cards
Dimensions (H x W x D, mm) : 440 x 260 x 700
Weight (kg) : 86
Warranty : 2 Yrs On-Site Service by Eaton (Thailand)
Technical specifications
Rating (VA/W) : 11000VA/10000W
Electrical characteristics
Technology : On-line double-conversion with Power Factor Correction (PFC) system
Input Voltage Range : 176-276V without derating (up to 100–276V with derating)
Input frequency range/THDI : 40-70Hz, 50/60Hz autoselection, frequency converter as standard, THDI < 5%
Efficiency : Up to 95% in Online mode, 98% in Hi-Efficiency mode
Connections
Input : Terminal block (up to 16mm)
Outputs : Terminal block
Outputs with HotSwap Maintenance Bypass : Terminal block + 4 IEC C19 (16A)
Communication
Communication ports : 1 USB port, 1 RS232 serial port (USB and RS232 ports cannot be used simultaneously)
4 dry contacts (DB9), 1 mini terminal block for remote On/ Off and 1 for remote power Off
1 DB15 for parallel operation
Communication slot : 1 slot for Network-MS card, ModBus-MS or Relay-MS cards
Dimensions (H x W x D, mm) : 440 x 260 x 700
Weight (kg) : 86
Warranty : 2 Yrs On-Site Service by Eaton (Thailand)